PTx seriesAsk about product

Product description

PTx series, AC/AC group, like other displacement transducers made by Peltron are based on the differential transformer principle – LVDT.  The transformer is placed inside a cylindrical case. There is a magnetic core inside the transformer. Displacement of the core results in a change in the transducer’s output signal.  This series is not equipped with a return spring so the core’s end has to be fixed to a moveable object. One transducer of PTx series works with a one channel conditioner like amplifier WG06.  These transducers are used in static and dynamic measurements like: displacements, materials length and thickness change, construction and machine elements deflections.

Documents for download

Technical parameters

Measure ranges [mm] 6,10,20,30,50,100,200,300
Power supply 2 Vrms, 5÷15 mA, 5 kHz
Output signal ±1 Vrms ±10%
Accuracy [%] MR ▪ ≤0,5
▪ ≤0,25
▪ ≤0,1
Operating temperature [°C] ▪ -20÷+80 standard
▪ -20÷+120
▪ -20÷+200
Ø body 14 mm
Ø core 4 mm
Electrical connection PVC cable ½ m no connector
Case material 316L
Return spring no